Asset ID: |
1-72-2084667.1 |
Update Date: | 2017-05-22 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2084667.1
:
SL8500, HP LTO6 - Replacement FRU, Ethernet Port Needed For Encryption is Missing
Related Items |
- HP LTO6 Tape Drive
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Applies to:
HP LTO6 Tape Drive - Version All Versions and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
SL8500, HP LTO6 replacement fru, Ethernet Port needed for encryption is missing.
We sent HP LTO6 FRU to replace a broken drive and the FE says that the drive was delivered without the Ethernet Port.
Can this be possible ?
The Ethernet Port needed to configure encryption.
7048529 [F] HP LTO6 8Gb FC Tape Drive , delivered without Ethernet Port ?
Is this the only HP LTO6 FRU that we can order ?
General
Drive Type : HpUltrium6
Code Version : J3ES-018.551
Vendor : HP
Serial Number : HU13500FRR
Interface Type : Fibre
Drive Configuration
World Wide Name Node : 50:01:04:f0:00:8a:64:1d
Port A World Wide Name : 50:01:04:f0:00:8a:64:1e
Port A Enabled : true
Port A Loop ID : auto
Port A Speed (GB) : 8 GBIT
Port A Link status : Initialized
Port B World Wide Name : 50:01:04:f0:00:8a:64:1f
Port B Enabled : true
Port B Loop ID : auto
Port B Speed (GB) : N/A
Port B Link status : Uninitialized
Cause
Confusion with cables.
Solution
There isn't an actual Ethernet port on the back of the drive. It is a serial connection on the back of the drive and we connect a serial to Ethernet cable that allows you to connect an Ethernet cable to back of the drive tray for the drive.
Just look at the bad drive connections closely before you disconnect anything and you'll see where the Ethernet to serial cable connects to the back of the drive.
The SL8500 Service Guide covers the various cable connections on the back of the different drive types.

Attachments