Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2084667.1
Update Date:2017-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  2084667.1 :   SL8500, HP LTO6 - Replacement FRU, Ethernet Port Needed For Encryption is Missing  


Related Items
  • HP LTO6 Tape Drive
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

HP LTO6 Tape Drive - Version All Versions and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 SL8500, HP LTO6 replacement fru, Ethernet Port needed for encryption is missing.

We sent HP LTO6 FRU to replace a broken drive and the FE says that the drive was delivered without the Ethernet Port.
Can this be  possible ?
The  Ethernet Port needed  to configure encryption.

7048529 [F]     HP LTO6 8Gb FC Tape Drive  , delivered without Ethernet Port ?

Is this the only HP LTO6 FRU that we can order ?

                  General
                     Drive Type : HpUltrium6
                     Code Version : J3ES-018.551
                     Vendor : HP
                     Serial Number : HU13500FRR
                     Interface Type : Fibre
                  Drive Configuration
                     World Wide Name Node : 50:01:04:f0:00:8a:64:1d
                     Port A World Wide Name : 50:01:04:f0:00:8a:64:1e
                     Port A Enabled : true
                     Port A Loop ID : auto
                     Port A Speed (GB) : 8 GBIT
                     Port A Link status : Initialized
                     Port B World Wide Name : 50:01:04:f0:00:8a:64:1f
                     Port B Enabled : true
                     Port B Loop ID : auto
                     Port B Speed (GB) : N/A
                     Port B Link status : Uninitialized

Cause

Confusion with cables.

Solution

There isn't an actual Ethernet port on the back of the drive.  It is a serial connection on the back of the drive and we connect a serial to Ethernet cable that allows you to connect an Ethernet cable to back of the drive tray for the drive.

Just look at the bad drive connections closely before you disconnect anything and you'll see where the Ethernet to serial cable connects to the back of the drive.

The SL8500 Service Guide covers the various cable connections on the back of the different drive types.