Solution Type  Problem Resolution Sure

Solution  2084377.1 :   SL150 - Local Web Console Inverted  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

SL150 - Local Web console inverted.

Operator Panel is showing data upside down.

Op Panel

Cause

Old Seiko OP Panels have an issue with the KLO card on the OP Panel.

 

OperatorPanelController       Operative      false       PN is 7058392

 

Solution

 Replace the OP Panel.