![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2082023.1 : L700e - T10000B Drives In Library Not Displaying Information Such As Vendor, Model, Etc
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek L700e Tape Library - Version All Versions and laterInformation in this document applies to any platform. - Is the L700 currently running at this time? Yes - Are there any service LEDs on? No - What is the physical configuration of the library? 8 T10000b drives. 618 slots - How many drives are in the library? 8 - What is the firmware level on the library and drives? Library firmware 3.18.02. Drive firmware all @ 1.52.203 - Why was the drive rebooted originally? new to this site. trying to get it into production - What was going on at time of problem? getting library running for use - Has there been any configuration or software changes recently? This is how it was running at the previous site. SymptomsHaving issues with L700 library with T10000b drives. Upon reboot, drives no longer show information such as Vendor, Model, Serial Number, Firmware Version. This is an extract from the logs uploaded
Changes
CauseDefective controller card. Solution Changed the MPCL card on the library to resolve issue. Created from <SR 3-11741127571> Applies to:Sun StorageTek L700e Tape Library References<NOTE:1364929.1> - How to Collect Statistical and Error Logs From L180/ L700e, L1400 Library:ATR:1364929.1:2Attachments This solution has no attachment |
||||||||||||||||||||||||
|