Asset ID: |
1-72-2081939.1 |
Update Date: | 2016-08-29 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2081939.1
:
Diameter Signaling Router (DSR) - Multiple Connections Bouncing To MP3 Following Software Release 7.0.1 Upgrade
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-11726433881>
Applies to:
BNS Platform Hardware - Version DSR 5.0 and later
Information in this document applies to any platform.
Symptoms
A total of 7 connections are bouncing following DSR release 7.0.1 upgrade to Odd MP cards.
Cause
It looks like connections to one MP are affected. In each of the errors reporting in the alarm history it states a "DWR/DWA based proving algorithm failure".
Each of the errors reporting in the alarm history it states a "DWR/DWA based proving algorithm failure".
Solution
Mobility Management Entity (MME) needs to be restarted.
Attachments
This solution has no attachment