Solution Type  Problem Resolution Sure

Solution  2081438.1 :   T10000D - Loading Code To a T10000D Drive From a Code Load Tape Does Not Work  


Related Items
  • StorageTek T10000D Tape Drive
  •  
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Loading Code to a T10000C/D Drive from a Code Load Tape does not work.

Cause

Firmware issue.

Solution

Loading code to a T10000D Drive from a Code Load Tape does not work as it will only load the functional code file. The other 4 FPGA code load files will not load.  For this reason do not use a code load tape to load code onto T10000C/D drives. 