Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2078947.1
Update Date:2018-05-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2078947.1 :   SL3000 - 1319 Robot Operation Failed - Hand Initialize  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Informational
Created from <SR 3-11725674208>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

The library reported a service required and then a reboot/power cycle of the library left it unresponsive in the audit library state.

Symptoms

Reboot/power cycle of the library left it unresponsive in the audit library state.

Current Library Configuration and Status:

ADI-Enabled: false

Address     Serial #          FRU Info       State  Type   codeMismatch libCommunicationFail
1,1,0,1,0 HBB 70002452 HBB 70002452 Error  robot    false                false                       INVESTIGATE Error Status


Robot 11010 appears to have issues

2015-11-17T09:03:29.519, 1.0.0.0.0, root, default, internal, 0, warn, 3811, "Library started - version FRS_4.31 - Active"
2015-11-17T09:06:03.807, 1.1.0.1.0, root, default, internal, 0, error, 1319, "Robot operation failed - handInitialize""

Robot is experiencing init failure due to a gripper issue.
  Init of grip and or reach failed, cannot init; servo mech grip event
 

Cause

Defective hardware.

 

Solution

Verify that there is no cartridge in the gripper.

If there is a cartridge in the gripper, remove cartridge and re initialize robot.
If there initialization fails replace the robot 1.1.0.1.0

If there is no cartridge in the gripper replace robot 1.1.0.1.0

Required part to be replaced.
7056590 [F] SL3000 Robot Assembly
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.