Solution Type Problem Resolution Sure Solution 2077349.1 : Dbnodeupdate Fails upgrading To 12.1.2.2.0 with dependencies related to elfutils, and ntsysv packages
Created from <SR 3-11684890161> Applies to:Exadata X3-2 Hardware - Version All Versions and laterInformation in this document applies to any platform. Symptomsdbnodeupdate fails upgrading from 12.1.2.1.2 to 12.1.2.2.0 dbnodeupdate.log shows errors related to dependencies. --> Finished Dependency Resolution
Error: Package: glibc-devel-2.12-1.149.el6_6.7.i686 (installed) Requires: glibc-headers = 2.12-1.149.el6_6.7 Removing: glibc-headers-2.12-1.149.el6_6.7.x86_64 (installed) glibc-headers = 2.12-1.149.el6_6.7 Updated By: glibc-headers-2.12-1.166.el6_7.1.x86_64 (exadata_generated_101115160654) glibc-headers = 2.12-1.166.el6_7.1 Error: Package: elfutils-libelf-devel-0.158-3.2.el6.x86_64 (installed) Requires: elfutils-libelf(x86-64) = 0.158-3.2.el6 Removing: elfutils-libelf-0.158-3.2.el6.x86_64 (installed) elfutils-libelf(x86-64) = 0.158-3.2.el6 Updated By: elfutils-libelf-0.161-3.el6.x86_64 (exadata_generated_101115160654) elfutils-libelf(x86-64) = 0.161-3.el6 Error: Package: glibc-2.12-1.149.el6_6.7.i686 (installed) Requires: glibc-common = 2.12-1.149.el6_6.7 Removing: glibc-common-2.12-1.149.el6_6.7.x86_64 (installed) glibc-common = 2.12-1.149.el6_6.7 Updated By: glibc-common-2.12-1.166.el6_7.1.x86_64 (exadata_generated_101115160654) glibc-common = 2.12-1.166.el6_7.1 Error: Package: elfutils-0.158-3.2.el6.x86_64 (installed) Requires: elfutils-libs(x86-64) = 0.158-3.2.el6 Removing: elfutils-libs-0.158-3.2.el6.x86_64 (installed) elfutils-libs(x86-64) = 0.158-3.2.el6 Updated By: elfutils-libs-0.161-3.el6.x86_64 (exadata_generated_101115160654) elfutils-libs(x86-64) = 0.161-3.el6 Error: Package: elfutils-0.158-3.2.el6.x86_64 (installed) Requires: elfutils-libelf(x86-64) = 0.158-3.2.el6 Removing: elfutils-libelf-0.158-3.2.el6.x86_64 (installed) elfutils-libelf(x86-64) = 0.158-3.2.el6 Updated By: elfutils-libelf-0.161-3.el6.x86_64 (exadata_generated_101115160654) elfutils-libelf(x86-64) = 0.161-3.el6 Error: Package: ntsysv-1.3.49.3-2.el6_4.1.x86_64 (installed) Requires: chkconfig = 1.3.49.3-2.el6_4.1 Removing: chkconfig-1.3.49.3-2.el6_4.1.x86_64 (installed) chkconfig = 1.3.49.3-2.el6_4.1 Updated By: chkconfig-1.3.49.3-5.el6.x86_64 (exadata_generated_101115160654) chkconfig = 1.3.49.3-5.el6 You could try using --skip-broken to work around the problem ** Found 3 pre-existing rpmdb problem(s), 'yum check' output follows: exadata-sun-computenode-exact-12.1.2.1.2.150617.1-1.x86_64 has missing requires of config(irqbalance) = ('2', '1.0.4', '10.0.3.el6') exadata-sun-computenode-exact-12.1.2.1.2.150617.1-1.x86_64 has missing requires of irqbalance = ('2', '1.0.4', '10.0.3.el6') exadata-sun-computenode-exact-12.1.2.1.2.150617.1-1.x86_64 has missing requires of irqbalance(x86-64) = ('2', '1.0.4', '10.0.3.el6')
CauseThis is due to unpublished Bug 21627981 YUM UPDATE TO 121220 FAILS DUE TO ELFUTILS
SolutionNeed to download latest dbnodeupdate Release 5.151022 included in patch 16486998 that includes fix. References<BUG:21627981> - YUM UPDATE TO 121220 FAILS DUE TO ELFUTILSAttachments This solution has no attachment |
||||||||||||
|