Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2076102.1
Update Date:2018-05-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2076102.1 :   T10000D - FSC BA07, RO_FSC_TAPE_EXPIRED  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Informational
Created from <SR 3-11667104631>

Applies to:

StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

T10000D with FSC BA07

Library 2 Drive 104102 Errors

Cause



(FSC Match Found in Rev. 4.08)
FSC: BA07 HD_FSC_SCAN_TIMEOUT
MIM Code: NONE
FRU: HARDWARE   CONF: 50%
FRU: MICROCODE   CONF: 50%
Summary: |***             | ***            | ***            |
Field Text:
Timed out while performing head actuator constant velocity scan
motion.
drive 57900400xxxx =  WD0870 (x2) XD0139 (x1) WD0278 (x1) WD0916 (x1)

Support Annotations:
T10000A/B/C/D - BA07 FSC - This is most likely a drive with defective hardware.

All tapes mentioned by customer did experience BA07.
 

Solution

Drive needs replacement due to FSC BA07, appears to be a DOA.

T10000A/B/C/D - BA07 FSC - This is most likely a drive with defective hardware.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.