Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2075759.1
Update Date:2017-04-07
Keywords:

Solution Type  Problem Resolution Sure

Solution  2075759.1 :   T2000 Host processor error  


Related Items
  • Sun Fire T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: Tx000
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-11667960071>

Applies to:

Sun Fire T2000 Server - Version All Versions to All Versions [Release All Releases]
Oracle Solaris on SPARC (64-bit)
Oracle Solaris on SPARC (32-bit)

Symptoms

System powered down, unable to power on again.

After multiple attempts to powercycle. Same fault occurs

 

SC Alert: Host System has Reset
NOV 06 15:24:14 ERROR: No functional CPUs available
NOV 06 15:24:14 FATAL: No cpus in bootset
NOV 06 15:24:16 FATAL: The HOST Processor has a configuration error, forcing a power-down

sc> showfaults -v
No failures found in System

 

 

Cause

The HOST processor has a configuration issue
The HOST processor is failed

Solution

Recommended Action Plan: Replace system board for faulted CPU's