Solution Type  Problem Resolution Sure

Solution  2072432.1 :   Slow Response When Configuring Network Settings on Windows Server 2012 R2  


Related Items
  • Sun Server X4-2L
  •  
  • Oracle Server X5-2
  •  
  • Sun Server X4-2
  •  
  • Sun Server X3-2
  •  
  • Sun Server X3-2L
  •  
  • Oracle Server X5-2L
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Server>SN-x86: Oracle Server X5
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-10848251501>

Applies to:

Sun Server X3-2L - Version All Versions and later
Oracle Server X5-2 - Version All Versions and later
Oracle Server X5-2L - Version All Versions and later
Sun Server X4-2 - Version All Versions and later
Sun Server X4-2L - Version All Versions and later
Information in this document applies to any platform.

Symptoms

When trying to configure the network settings on a server with Windows Server 2012 R2 and OHMP installed, the network settings window looks like it has hung or it is really slow to respond.

This issue might impact third-party licensing programs that regularly queries the MACs to check the license.

It may affect VMware Workstation as well, where the VM's bridged network stops working

 

Cause

This issue is caused by a Windows virtual NIC driver in OHMP.

Please see the following bug 20272374

Solution

A workaround for this issue is to reboot the ILOM. Once the ILOM is rebooted the network configuration window response is back to normal.

Install OHMP 2.3.3.0 on the affected server to resolve this issue. This is patch 21969558 Oracle HMP 2.3.3 for Microsoft Windows 2003/2008

NOTE: The patch description is wrong it is going to be fixed soon.
This patch version supports all Windows versions supported by a given hardware platform (except Microsoft Windows 2003).

 

References

<BUG:20272374> - NO RESPONSE AFTER SOME IDLE MINUTES IN "TASK MANAGER" -> "NETWORKING" WINDOW
<BUG:20259399> - CONCORDSW1.4: W2K8R2 TAKES 2~4 MINUTES SHOW INTEL NIC CARD PROPERTY LEGACY MODE
<BUG:20307003> - MANY "LIBSES ERROR " EVENTS SEEN.
Support Matrix for Oracle Hardware Management Pack 2.3.3 http://www.oracle.com/technetwork/server-storage/servermgmt/tech/hardware-management-pack/support-matrix-2-3-3-2720672.html
<BUG:21080170> - X5-2LSW1.2: W2012R2 TAKES 2~4 MINUTES TO SHOW NIC PROPERTY