Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2072127.1
Update Date:2017-08-31
Keywords:

Solution Type  Problem Resolution Sure

Solution  2072127.1 :   Upgrade IB Switch To 2.1.5 - Verify-topology Error - Multirack IB  


Related Items
  • Exadata X3-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Created from <SR 3-11498104141>

Applies to:

Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Trying to upgrade IB switch, multirack IB network from version 2.1.3 to version 2.1.5 (patch 12.1.2.1.1 and patch 12.1.2.1.2 - 20748218) we see following error doing the precheck and running the upgrade:

  ----- InfiniBand switch update process ended Thu Oct 8 09:39:54 CEST 2015 -----
  [ERROR ] [ERROR]
  [ERROR ] [ERROR]
  [FAIL ] Validating verify-topology output
  [FAIL ] Overall status

 

Cause

Customer is having multirack with 3 Exadata, 3 BigData and 1 Storage Server
 
IB network of this customer, with 3 Exadata + 3 Big Data + 1 Storage Expansion is not supported by verify-topology (tool include in "patchmgr"), version checked 12.1.2.2.0, 12.1.2.1.1, 12.1.2.1.2, so is not possible to pass correctly the "patchmgr" pre requisites, and due to this the upgrade of IB switch was done with the option "-force", method preferred to the manual upgrade.
 

Solution

 The IB switches were upgraded using the patchmgr tool and with the "-force" option (./patchmgr -ibswitches -upgrade -force)

Before to upgrade each IB switch was checked with the  "./patchmgr –ibswitches -upgrade -ibswitch_precheck", from the log generated it can checked that only there were errors due to verify-topology.

To patch to IB version 2.1.5 it was used 12.1.2.1.2, it was  no used 12.1.2.2.0 patch,as this patch fails too due to verify-topology as the IB network has ExaData and BigData racks connected 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback