![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2071864.1 : Fujitsu M10-4S: Error: 01e40001 - XSCF self diagnosis warning detection
In this Document
Applies to:Fujitsu M10-4S - Version All Versions and laterInformation in this document applies to any platform. SymptomsThe "XSCF self diagnosis warning detection" error can occur on the M10-4S when there are more than 2 building blocks ( BB's ), or when there are XBBox's in a multi node system. The problem was introduced in XCP2250 and can be experienced in XCP versions 2250 - 2271. Sample Error: Date: Sep 15 10:42:38 HKT 2015
Code: 20000000-00560300fcff0000ff-01e400010000000000000000 Status: Notice Occurred: Sep 15 10:43:08.531 HKT 2015 FRU: /BB#2/CMUL,/FIRMWARE Msg: XSCF self diagnosis warning detection Diagnostic Code: 02000000 00000000 0000 00000000 00000000 0000 00000000 00000000 0000 00000000 00000000 00000000 00000000 00000000 00000000 0000 CauseThe syncdate file fails regeneration after it is deleted by switching of the Master XSCF when using XCP2250 or later. Because XSCF cannot synchronize TOD between Master and Slave chassis, the time differential may be generated between CMU-TOD and XSCF on the Slave chassis when the system is powered on for a long time. SolutionWorkaround: Re-boot the XSCF on the Slave chassis when the switching of Master XSCF occurred in the above conditions.
See also QQMS INCO1-151007-001 References<BUG:21952175> - ERROR CODE 01E40001 - XSCF SELF DIAGNOSIS WARNING DETECTIONAttachments This solution has no attachment |
||||||||||||||||||
|