Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2071864.1
Update Date:2015-10-29
Keywords:

Solution Type  Problem Resolution Sure

Solution  2071864.1 :   Fujitsu M10-4S: Error: 01e40001 - XSCF self diagnosis warning detection  


Related Items
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M10
  •  




In this Document
Symptoms
Cause
Solution
References


Applies to:

Fujitsu M10-4S - Version All Versions and later
Information in this document applies to any platform.

Symptoms

The "XSCF self diagnosis warning detection" error can occur on the M10-4S when there are more than 2 building blocks ( BB's ), or when there are XBBox's in a multi node system.
The issue will be seen when the Master XSCF is switched due to a reboot ( flashupdate, xscfreboot ... ect ).

The problem was introduced in XCP2250 and can be experienced in XCP versions 2250 - 2271.

Sample Error:

Date: Sep 15 10:42:38 HKT 2015
   Code: 20000000-00560300fcff0000ff-01e400010000000000000000
   Status: Notice                 Occurred: Sep 15 10:43:08.531 HKT 2015
   FRU: /BB#2/CMUL,/FIRMWARE
   Msg: XSCF self diagnosis warning detection
   Diagnostic Code:
       02000000 00000000 0000
       00000000 00000000 0000
       00000000 00000000 0000
       00000000 00000000 00000000 00000000
       00000000 00000000 0000

Cause

The syncdate file fails regeneration after it is deleted by switching of the Master XSCF when using XCP2250 or later.

Because XSCF cannot synchronize TOD between Master and Slave chassis, the time differential may be generated between CMU-TOD and XSCF on the Slave chassis when the system is powered on for a long time.

Solution

Workaround:

Re-boot the XSCF on the Slave chassis when the switching of Master XSCF occurred in the above conditions.

  1. Log in to the Master XSCF
  2. Perform "rebootxscf -b bb_id" or "rebootxscf -a"
  3. Verify Correct TOD of the logical domain on Slave chassis.  If necessary correct TOD with the date(1) command or using NTP function.

See also QQMS INCO1-151007-001

References

<BUG:21952175> - ERROR CODE 01E40001 - XSCF SELF DIAGNOSIS WARNING DETECTION