In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-11551677611>

Applies to:

Sun Storage 7210 Unified Storage System - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

SP error message noted:

Error Codes
---------------------------------------------------
Oct 15 02:59:01 172.16.16.14 plathwsvcd[935]: [935 CRITICAL][libipmi_session.c:364]New priv level is 4

 

Cause

Bug:19731186 - LIBIPMI FUNCTIONS LOGGING MESSAGES TO SYSLOG

 

Solution

Isolated errors to CR 19731186,  fixed in ILOM version 3.2.6,  but 7210 is only qualified for ILOM 2.x.