Solution Type  Problem Resolution Sure

Solution  2071034.1 :   T10000A/B - RTDs Show Dump - SNO 1700  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  


FICON RTDs with DMP 1700 in display

In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Informational
Created from <SR 3-11598222881>

Applies to:

Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

T10000B FICON RTDdrives have dumps / SNOs in drive with FSC 1700

Changes

 

Cause

SNO-1700: 10/20/2015 02:37:03.034

This is an ASIA/DIA SNO. ASIA FSC is 1700
 
FSC Dictionary Description:
MODEL = T10000B
FSC = 1700
(FSC Match Found in Rev. 1.50)


FSC: 1700 ASC_FSC_INV_SAV_CH_STA_ST_ACPT
MIM Code: INOPERABLE
FRU: MICROCODE CONF: 100%
Summary: |INVALID UCODE |DATA RECEIVED | *** |

Field Text:
Invalid status was present when a status accepted frame was received and the device lock was not held.
 

Solution

No action required, works as designed for T10000A/B.  Drive issues are addressed in T10000C/D drives firmware.
 