Created from <SR 3-11544892451> Applies to:Sun StorageTek VSM5 System - Version All Versions and laterIBM z/OS on System z SymptomsVSM5 with VCF4 will not connect to an IBM Z13 processor with Ficon express 16gb Channels NOTE: The following actions are to be performed by a VSM Service Engineer
Internal VSM files may indicate the following symptoms. REC:11528 15/09/01 at 11:37:55 C01C FSC8965_QLOGIC_STATE_CHANGE: Performing or waiting to perform link initialization, LED State: 0x01000000
REC:11529 15/09/01 at 11:37:55 C01C FSC8959_SFP_RX_LOS_DEASSERTED REC:11530 15/09/01 at 11:37:55 C01C FSC8965_QLOGIC_STATE_CHANGE: Attempting port login, LED State: 0x02000000 REC:11531 15/09/01 at 11:37:55 C01C FSC8969_FLOGI_NOT_COMPLETE REC:11532 15/09/01 at 11:37:55 C01C FSC8969_FLOGI_NOT_COMPLETE
CauseThe Ficon interface will not perform the fiber channel log in process SolutionPerform a GFR NO-replace of the affected VCF card. When the GFR completes, ensure the VCF port links up with the channel. Review the Table A-8 labeled VCF Card Link Status LED Blink-Pattern Descriptions for the meaning of the VCF card LEDs, in the section of the current VSM5 Installation and Maintenance Guide E21135-03. A successful FLOGI log in be indicated as shown below: REC:17732 15/10/19 at 11:47:33 C01C FSC896B_CU_ELP_SUCCESS, remote N_Port id: 000c00, pdb idx: 00, ch img: 02, cu img: 0b