Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2068524.1
Update Date:2017-08-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  2068524.1 :   SL3000 - Handboot Offline "Failure From Robot Code: 503 - Robot Needs To Be Inoperative"  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-11487565861>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Handboot Offline "Failure From Robot Code: 503 - Robot Needs To Be Inoperative"

ddress       Serial #         FRU Info          State          Type                codeMismatch   libCommunicationFail  
1,0,0,0,0     none          HBCR  74001273    Ready          library             false          false                  
1,0,0,1,0                      HBT   74203453                   drive_controller    false          false                  
1,1,0,1,0                      HBB   74032436   HBB   74032436    Ready          robot               false          false                  
1,1,0,2,0                      HBB   74036958   HBB   74036958    Error          robot               false          false                  INVESTIGATE Error Status      <---------  Problem on 1,1,0,2,0
1,1,11,2,0                   
HBCR  74001273    Ready          cap                 false          false                  
1,1,5,2,0                      HBCR  74001273    Ready          cap                 false          false

2015-10-05 09:40:07 Rail 1    Bot(1.1.0.2.0)
1302 - (1X)
Failure from robot Code: 503 - Robot needs to be inoperative, cmo_user_fetch: Retry Performed 5610; servo mech grip event 5065   hliLsm=0 address = Cell(1,1,7,1,21)
B12064L6 (x1)
20 mils  (1X)
(Errors Started - 2015-10-05 09:40:07 Errors Stopped - 2015-10-05 09:40:07)
3955 - (2X)
Error from device Code: 505 - Robot says location is empty,  address = Drive_Bay17(1,1,4,1,5)
Error from device Code: 503 - Robot needs to be inoperative, cmo_user_fetch: Retry Performed 5610; servo mech grip event 5065  address = Cell(1,1,7,1,21)
20 mils  (1X)
(Errors Started - 2015-09-27 17:55:17 Errors Stopped - 2015-10-05 09:40:01)
3992 - (3X)
Warning from device, cmo_user_put: Retry Performed 5611; servo mech grip event 5065  address = Cell(1,1,26,2,40)
Warning from device, cmo_user_fetch: Retry Performed 5610;  address = Cell(1,1,26,2,40)
Warning from device, cmo_user_fetch: Retry Performed 5610; servo mech grip event 5065  address = Drive_Bay19(1,1,2,1,5)
259 mils  (1X)
70 mils  (1X)
(Errors Started - 2015-10-03 13:17:01 Errors Stopped - 2015-10-05 08:49:10)

Cause

Defective robot.

Solution

Replaced robotic module.