Asset ID: |
1-72-2068524.1 |
Update Date: | 2017-08-08 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2068524.1
:
SL3000 - Handboot Offline "Failure From Robot Code: 503 - Robot Needs To Be Inoperative"
Related Items |
- Sun StorageTek SL3000 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-11487565861>
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Handboot Offline "Failure From Robot Code: 503 - Robot Needs To Be Inoperative"
ddress Serial # FRU Info State Type codeMismatch libCommunicationFail
1,0,0,0,0 none HBCR 74001273 Ready library false false
1,0,0,1,0 HBT 74203453 drive_controller false false
1,1,0,1,0 HBB 74032436 HBB 74032436 Ready robot false false
1,1,0,2,0 HBB 74036958 HBB 74036958 Error robot false false INVESTIGATE Error Status <--------- Problem on 1,1,0,2,0
1,1,11,2,0 HBCR 74001273 Ready cap false false
1,1,5,2,0 HBCR 74001273 Ready cap false false
2015-10-05 09:40:07 Rail 1 Bot(1.1.0.2.0)
1302 - (1X)
Failure from robot Code: 503 - Robot needs to be inoperative, cmo_user_fetch: Retry Performed 5610; servo mech grip event 5065 hliLsm=0 address = Cell(1,1,7,1,21)
B12064L6 (x1)
20 mils (1X)
(Errors Started - 2015-10-05 09:40:07 Errors Stopped - 2015-10-05 09:40:07)
3955 - (2X)
Error from device Code: 505 - Robot says location is empty, address = Drive_Bay17(1,1,4,1,5)
Error from device Code: 503 - Robot needs to be inoperative, cmo_user_fetch: Retry Performed 5610; servo mech grip event 5065 address = Cell(1,1,7,1,21)
20 mils (1X)
(Errors Started - 2015-09-27 17:55:17 Errors Stopped - 2015-10-05 09:40:01)
3992 - (3X)
Warning from device, cmo_user_put: Retry Performed 5611; servo mech grip event 5065 address = Cell(1,1,26,2,40)
Warning from device, cmo_user_fetch: Retry Performed 5610; address = Cell(1,1,26,2,40)
Warning from device, cmo_user_fetch: Retry Performed 5610; servo mech grip event 5065 address = Drive_Bay19(1,1,2,1,5)
259 mils (1X)
70 mils (1X)
(Errors Started - 2015-10-03 13:17:01 Errors Stopped - 2015-10-05 08:49:10)
Cause
Defective robot.
Solution
Replaced robotic module.
Attachments
This solution has no attachment