![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2068423.1 : T10000B - IEHINITT Fails on ALP Tapes, FSC 40B3
In this Document
Created from <SR 3-11508627401> Applies to:Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases]IBM z/OS on System z Customer want to re-label 200+ T10KB MVC ALP tapes. This is to change the recorded volser on each of the MVC from BAxxxx to BZxxxx All the tapes were DRAINED and removed for the MVCPOOL. A RTD was varied offline and changed to 3590 emulation to be used as native drive to run the IEHINITT re-label batch job from the MVS host. SymptomsThe IEHINITT batch job fails to initialize ALP tapes with a permanent error FSC 40B3 --------------------------------------------------------
CauseTape engineering analysis shows the tape was NOT re-initialized to a non-ALP tape, therefore the IEHINIT will not be able to write on the tape, until the tape is no longer an ALP tape. MVS utilities can not deal with an ALP tape. SolutionTapes will have to be converted to standard tapes using VSM tools, and then can be re-labeled using MVS tools. The tapes can be added back to VSM tape pool. Following update: (17-Nov, 2015) Doc id: 2068423.1
References<BUG:22047220> - IEHINITT FAILS TO RE-LABEL ALP MVC WITH A PERM FSC 40B3Attachments This solution has no attachment |
||||||||||||||||||
|