IR-66 - False SCTP Path Failure Alarm 22103 And 2 CEA Send When RTT Is Over 120ms
Related Items |
- Oracle Communications Diameter Signaling Router (DSR)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-10272612431>
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 and later
Information in this document applies to any platform.
Symptoms
A second CEA transmitted by DSR when connection is set to 500ms as RTO min
Cause
Second captured on the secondary path
Solution
Responder connections are configured with the local node attributes and reconfigured with connection attributes, when capabilities exchange completes. Default is 120ms.
References
<NOTE:2024837.1> - Change False SCTP alarms (Alarm ID #22103) from a MINOR to a INFO alarm.
<BUG:20539431> - [PERFCAP7.0] UNEXPECTED SCTP CONNECTION IMPAIRED ALARMS ON NON-MH CONNECTIONS