![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2064603.1 : SL150 - Medium Changer Not Present, VMware Does Not Support Multi LUN Configuration
In this Document
Created from <SR 3-11472261961> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsThe sl150 has 2x SAS LTO6 drives connected direct to the backups host which are passed through to the VMware ChangesNew configuration. CauseVMWare does not support scsi multi luns environment. VMWare detected 2 LTO tape drives as t0 lun 0 and t1 lun 0 as ACTIVE, but t0 lun 1 as DEAD.
SolutionBypass VMWare. Note: ESXi/ESX supports vendor-supported parallel SCSI tape drives and tape libraries only. If you are using a tape drive library (versus using a stand-alone tape drive), the library must be multi-target, and not multi-LUN. Ensure that the tape drive's virtual target ID in the virtual machine's configuration is set to be the same as the physical target ID.
Attachments This solution has no attachment |
||||||||||||||||||||
|