Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2064320.1
Update Date:2017-04-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  2064320.1 :   SS7 PMF Mistral Cards Do Not Show All Links on linkDisp on PIC 10.1.5 and 10.2  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-11499068741>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.1.5 and later
Information in this document applies to any platform.

Symptoms

PMF SS7 does not capture data on all links.

linkDisp do not show all links.

Changes

System was upgraded to PIC 10.1.5 (PMF 10.1.5.0.0-9.1.0).

Cause

This is caused by limitation implemented for IMF and PMF to improve performances.

This is applicable to SS7 PMF only.

Solution

Raise a SR mentioning this document reference.

Procedure:

  1. Connect on PMF as cfguser.
  2. Edit table "PartDef":
    ivi PartDef
  3. Modify line "34|MsuPart|Log|ABC|50|-1|212|12 ... " to " 34|MsuPart|Log|ABC|512|-1|212|12 ... ".
  4. Save the table (:x!) and enter "yes" when prompted to reload the table.
  5. Stop probeMonitor:
    pm.set off probeMonitor
  6. Start probeMonitor:
    pm.set on probeMonitor

References

<BUG:21967522> - MAXIMUM MISTRAL CARDS SS7 LINKS SET TO 50

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback