Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2064290.1
Update Date:2017-05-18
Keywords:

Solution Type  Problem Resolution Sure

Solution  2064290.1 :   SL150 - Fails to Audit Mail Slot  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

IHAC getting an error when they audit the mail slot. Replaced the robot but the new robot failed with the same error...put back with the old robot and currently library is operational but the mail slot still cannot be audited.
What target the is robot trying to find?

Symptoms

Latest log with using old robot:

2015-10-06T14:49:20.097 0000 0.0.13.0.1 5651 "cmo_calibrate_target failed to find target for address (Mailslot #) 3, cmo_status=3; cmo_target_vertical() visionStatus=2;
2015-10-06T14:49:20.131 0000 0.0.14.0.1 5651 "Director - auditResponse() cmo_calibrate_target failed to find target for address (Mailslot #) 3, cmo_status=3; cmo_target_vertical() visionStatus=2;

2015-10-06T15:10:04.905 0000 0.0.13.0.1 5651 "cmo_calibrate_target failed to find target for address (Mailslot #) 1, cmo_status=3; cmo_target_horizontal() visionStatus=2; cmo_target_horizontal: target not found for address (Mailslot #) 1;
2015-10-06T15:10:04.928 0000 0.0.14.0.1 5651 "Director - auditResponse() cmo_calibrate_target failed to find target for address (Mailslot #) 1, cmo_status=3; cmo_target_horizontal() visionStatus=2; cmo_target_horizontal: target not found for address (Mailslot #) 1;

The latest log from new robot:

2015-10-06T19:38:42.144 0000 0.0.12.0.1 5651 "cmo_calibrate_target failed to find target for address (Mailslot #) 1, cmo_status=3; cmo_target_horizontal() visionStatus=2; cmo_target_horizontal: target not found for address (Mailslot #) 1; End of Text" 000        robot-cmo   warn
2015-10-06T19:38:42.181 0000 0.0.12.0.1 5651 "Director - auditResponse() cmo_calibrate_target failed to find target for address (Mailslot #) 1, cmo_status=3; cmo_target_horizontal() visionStatus=2; cmo_target_horizontal: target not found for address (Mailslot #) 1;


Also found these error:

2015-10-06T19:49:40.922 0000 0.0.0.0.0 3300 "IFM cartridge with unreadable label at: (Mailslot #) 1 "                 3200              ifm   info
2015-10-06T19:50:00.936 0000 0.0.0.0.0 3300 "IFM cartridge with unreadable label at: (Mailslot #) 2 "                 3200              ifm   info

Cause

This all indicates a mail slot calibration issue.

Solution

Check the attached picture to reference the calibration target. It may be damaged, or the mail slot may not be seated properly.

Mail Slot Target

It is not a CRU currently.  You need to replace the whole chassis to get a new one.

 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback