SL150 - Fails to Audit Mail Slot
Related Items |
- StorageTek SL150 Modular Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
|
In this Document
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.
IHAC getting an error when they audit the mail slot. Replaced the robot but the new robot failed with the same error...put back with the old robot and currently library is operational but the mail slot still cannot be audited.
What target the is robot trying to find?
Symptoms
Latest log with using old robot:
2015-10-06T14:49:20.097 0000 0.0.13.0.1 5651 "cmo_calibrate_target failed to find target for address (Mailslot #) 3, cmo_status=3; cmo_target_vertical() visionStatus=2;
2015-10-06T14:49:20.131 0000 0.0.14.0.1 5651 "Director - auditResponse() cmo_calibrate_target failed to find target for address (Mailslot #) 3, cmo_status=3; cmo_target_vertical() visionStatus=2;
2015-10-06T15:10:04.905 0000 0.0.13.0.1 5651 "cmo_calibrate_target failed to find target for address (Mailslot #) 1, cmo_status=3; cmo_target_horizontal() visionStatus=2; cmo_target_horizontal: target not found for address (Mailslot #) 1;
2015-10-06T15:10:04.928 0000 0.0.14.0.1 5651 "Director - auditResponse() cmo_calibrate_target failed to find target for address (Mailslot #) 1, cmo_status=3; cmo_target_horizontal() visionStatus=2; cmo_target_horizontal: target not found for address (Mailslot #) 1;
The latest log from new robot:
2015-10-06T19:38:42.144 0000 0.0.12.0.1 5651 "cmo_calibrate_target failed to find target for address (Mailslot #) 1, cmo_status=3; cmo_target_horizontal() visionStatus=2; cmo_target_horizontal: target not found for address (Mailslot #) 1; End of Text" 000 robot-cmo warn
2015-10-06T19:38:42.181 0000 0.0.12.0.1 5651 "Director - auditResponse() cmo_calibrate_target failed to find target for address (Mailslot #) 1, cmo_status=3; cmo_target_horizontal() visionStatus=2; cmo_target_horizontal: target not found for address (Mailslot #) 1;
Also found these error:
2015-10-06T19:49:40.922 0000 0.0.0.0.0 3300 "IFM cartridge with unreadable label at: (Mailslot #) 1 " 3200 ifm info
2015-10-06T19:50:00.936 0000 0.0.0.0.0 3300 "IFM cartridge with unreadable label at: (Mailslot #) 2 " 3200 ifm info
Cause
This all indicates a mail slot calibration issue.
Solution
Check the attached picture to reference the calibration target. It may be damaged, or the mail slot may not be seated properly.

It is not a CRU currently. You need to replace the whole chassis to get a new one.