Solution Type Problem Resolution Sure Solution 2061653.1 : Eagle STP UIO Alarms Aren't Transferring To NETBOSS
In this Document
Created from <SR 3-11377589731> Applies to:Oracle Communications EAGLE (Software) - Version EMS 43.x and laterInformation in this document applies to any platform. SymptomsEagle STP UIO alarms are not being transferred to NETBOSS. CauseCOMMAND Processes stopped at the probuilder. SolutionCOMMAND Process at probuilder not running and also TRM wrong configuration at Eagle.
Check the to make sure the following are occurring: 1. In the probuilder verify STP EMSALM,CMD and General terminal is green. 2. Make sure 3 terminal is reserved for EMS (ALM, CMD, General) to connect to STP UIO. 3. In the CMI try to manually connect to STP and check the status. 4. Restart the command, general, alarm port of STP UIO in EMS Probuilder. Resolution: probuilder processes restarted and changing the TRM configuration all alarms was appearing instantaneously Attachments This solution has no attachment |
||||||||||||||||
|