Asset ID: |
1-72-2061629.1 |
Update Date: | 2017-02-15 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2061629.1
:
E5MS - SNMP NBI Acknowledge Synchronization Criteria Is Not Working
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
|
In this Document
Created from <SR 3-11421922761>
Applies to:
Oracle Communications EAGLE (Software) - Version E5-MS 45.0 to E5-MS 46.0 [Release E5-MS 45.0 to E5-MS 46.0]
Information in this document applies to any platform.
Symptoms
SNMP NBI Acknowledge synchronization criteria is not working
Cause
Severity "INFO" criteria not selected
Solution
Adding the "INFO" on filtered alarms, the synchronization is now working correctly
Attachments