Asset ID: |
1-72-2061127.1 |
Update Date: | 2015-10-08 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2061127.1
:
Fail to Load firmware 2.1.3_4 onto IB switch
Related Items |
- Exadata Database Machine X2-2 Hardware
|
Related Categories |
- PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
|
Created from <SR 3-11438989621>
Applies to:
Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Fail to Upgrade Switch From version 1.3.3-2 To 2.1.3_4 due to unsuccessful load operation
upgradeIBSwitch.log
=====================
[1443511922][2015-09-29 10:55:37 +0300][FAIL][/u01/patch/patch_12.1.1.1.2.150411/upgradeIBSwitch.sh][upgradeIBSwitch_print][] Load firmware 2.1.3_4 onto XXXXX-ib2
[1443511922][2015-09-29 10:55:37 +0300][INFO][/u01/patch/patch_12.1.1.1.2.150411/upgradeIBSwitch.sh][loadIBSwitchSW][] [CMD: load -source /tmp/sundcs_36p_repository_2.1.3_4.pkg]
[root@XXXXX-ib2 ~]# spsh
Oracle(R) Integrated Lights Out Manager
Version ILOM 3.0 r47111
Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
-> load -source /tmp/sundcs_36p_repository_2.1.3_4.pkg <<<<<<<<<<<<<<<<<<<<<
NOTE: Firmware upgrade will upgrade the SUN DCS 36p firmware.
ILOM will enter a special mode to load new firmware. No
other tasks should be performed in ILOM until the firmware
upgrade is complete.
Are you sure you want to load the specified file (y/n)? y
Setting up environment for firmware upgrade. This will take few minutes.
Starting SUN DCS 36p FW update
==========================
Performing operation: I4 A
==========================
I4 A: I4 is already at the given version.
===========================
Summary of Firmware update
===========================
I4 status : FW UPDATE - SUCCESS
I4 update succeeded on : none
I4 already up-to-date on : A
I4 update failed on : none
=========================================
Performing operation: SUN DCS 36p firmware update
=========================================
SUN DCS 36p upgrade from 1.3.3-2 to 2.1.3-4:
Upgrade started...
Upgrade completed.
INFO: SUN DCS 36p upgrade from 1.3.3-2 to 2.1.3-4 failed<<<<<<<<<<<<<<<<<<<<<<<<<<
Cause
sundcs_36p_repository_2.1.3_4.pkg package is not got transferred properly from compute node to IB switch during the patchmgr run
Logged into IB switch and checked the frimware log, there is an error while checking the signature of some rpms
installfw.stderr
===================
Error checking signature of package prelink-0.3.9-2.1.i386.rpm.<<<<<
Stopping MST (Mellanox Software Tools) driver set
Unloading MST PCI configuration module [60G[[0;32m OK [0;39m]
Unloading MST PCI module [60G[[0;32m OK [0;39m]
Unloading i2c driver ERROR: Module i2c_dev is in use
[60G[[0;31mFAILED[0;39m]
Solution
1) downgrade the IB Switch to 1.3.3-2
# patchmgr -ibswitches ibswitches.lst -downgrade -ibswitch_precheck
# patchmgr -ibswitches ibswitches.lst -downgrade
2) From ibswitch remove the temporary patch files from /tmp directory
sundcs_36p_repository_2.1.3_4.pkg
unpackerrors
filetWJwpT
magnumfw_repository
installfw.stderr
newflasher.lock
platform_events
json
ldalog
3) Rerun the IB switch upgrade once again
# patchmgr -ibswitches ibswitches.lst -upgrade -ibswitch_precheck
# patchmgr -ibswitches ibswitches.lst -upgrade