Solution Type  Problem Resolution Sure

Solution  2058459.1 :   T10000 - FSC: 5802 - Load Failed With Misbuckle  


Related Items
  • Sun StorageTek T10000 Data Cartridge
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-11363136391>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Sun StorageTek T10000 Data Cartridge - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

Multiple drive error reported on ACSLS console


2015-09-11 04:30:52 0 drive 1, 2, 1, 5: Library error, Media error
.
2015-09-11 04:34:16 0 drive 1, 3, 1,15: Library error, Media error
.
2015-09-11 04:36:11 0 drive 1, 3, 1,14: Library error, Media error
.
2015-09-11 04:37:40 0 drive 1, 2, 1, 5: Library error, Media error
.
2015-09-11 04:39:50 0 drive 1, 3, 1, 8: Library error, Media error
.
2015-09-11 04:41:25 0 drive 1, 3, 1,15: Library error, Media error
.
2015-09-11 04:44:03 0 drive 1, 3, 1,14: Library error, Media error

Cause

This tape cartridge "S50730T1 (216)" has failed to load for 216 times on multiple drives. The tape cartridge leader was out of buckling arm, misaligned.
 
S50730T1 (216)

===
Volumes with failures on multiple drives found in HBT logs:

S50730T1 - Drives: 1,4,-2,1,2 , 1,4,2,1,4 , 1,4,-2,1,3 , 1,4,-2,1,1 , 1,4,2,1,3 , 1,4,-1,1,1 , 1,3,-1,1,2 , 1,2,-2,1,1 , 1,3,-2,1,3 , 1,4,2,1,1 , 1,4,-1,1,3 , 1,4,1,1,1 , 1,4,1,1,4 , 1,4,-1,1,4 , 1,3,-2,1,2 , 1,3,-1,1,1 , 1,4,2,1,2 , 1,3,-2,1,4


3335 - (2X)
Drive has misbuckle error - on load, hliLsm=2
S50730T1 (x2)
(Errors Started - 2015-09-10 22:14:45 Errors Stopped - 2015-09-11 00:44:00)

3337 - (6X)
Drive load failed due to media error, hliLsm=2
S50730T1 (x6)
(Errors Started - 2015-09-10 17:49:02 Errors Stopped - 2015-09-11 07:11:19)

3955 - (8X)
Error from device Code: 605 - Drive media error, drive 1,3,-2,1,2: load FAILED with mediaError: (driveType = T10000a-Enc, driveFirmware = 1.50.103-5.30, sn = 531004009898) FSC: 5135
Error from device Code: 607 - Drive had a misbuckle error on load, drive 1,3,-2,1,2: load failed with misbuckle: (driveType = T10000a-Enc, driveFirmware = 1.50.103-5.30, sn = 531004009898) FSC: 5802
S50730T1 (x8)
(Errors Started - 2015-09-10 17:49:02 Errors Stopped - 2015-09-11 07:11:19)

3992 - (8X)
Warning from device, drive 1,3,-2,1,2: rewindUnload Successful with mediaError: , FSC: 5135
Warning from device, drive 1,3,-2,1,2: rewindUnload Successful with mediaError: , FSC: 5802
 

Solution

Action Plan:

Inspect the tape cartridge physically.

Check whether the tape cartridge leader is out of position.

If so, FE needs to repair the tape cartridge by using the tool.

In this case the customer had removed the tape cartridge from the library and the issue got fixed, monitored the drives activity for a week. No further alerts reported on their ACSLS console.
 