![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2056911.1 : Fujitsu M10-1/M10-4/M10-4S: Error: Get Device ID command failed: Unknown (0x7E) is displayed when running fwupdate
In this Document
Created from <SR 3-11028868431> Applies to:Fujitsu M10-1 - Version All Versions and laterFujitsu M10-4 - Version All Versions and later Fujitsu M10-4S - Version All Versions and later Information in this document applies to any platform. SymptomsWhen running the fwupdate command the following messages are displayed $ fwupdate list all
Get Device ID command failed: Unknown (0x7E) Get Device ID command failed: Unknown (0x7E) CauseThis message is displayed because the Hardware Maintenance Pack cannot connect XCP. SolutionSince updating the XCP firmware is not a supported Hardware Maintenance Pack function on this platform, this message can be ignored. References<NOTE:2062123.1> - Fujitsu M10-1/M10-4/M10-4S: Error: fwupdate Fails with Message "ERROR: Could not identify host type"<BUG:21458042> - SPARC M10-X SERVERS NEED FWUPDATE SUPPORT <NOTE:2047847.1> - Fujitsu M10: Firmware for the Various Hardware Components used on Fujitsu M10 <BUG:21849217> - HMP FAILED TO UPDATE HOST PROFILE AFTER AN OS/PKG UPDATE Attachments This solution has no attachment |
||||||||||||||||||
|