Solution Type  Problem Resolution Sure

Solution  2056911.1 :   Fujitsu M10-1/M10-4/M10-4S: Error: Get Device ID command failed: Unknown (0x7E) is displayed when running fwupdate  


Related Items
  • Fujitsu M10-1
  •  
  • Fujitsu M10-4S
  •  
  • Fujitsu M10-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M10
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-11028868431>

Applies to:

Fujitsu M10-1 - Version All Versions and later
Fujitsu M10-4 - Version All Versions and later
Fujitsu M10-4S - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 When running the fwupdate command the following messages are displayed

$ fwupdate list all
Get Device ID command failed: Unknown (0x7E)
Get Device ID command failed: Unknown (0x7E)

Cause

This message is displayed because the Hardware Maintenance Pack cannot connect XCP.

Solution

Since updating the XCP firmware is not a supported Hardware Maintenance Pack function on this platform, this message can be ignored.

References

<NOTE:2062123.1> - Fujitsu M10-1/M10-4/M10-4S: Error: fwupdate Fails with Message "ERROR: Could not identify host type"
<BUG:21458042> - SPARC M10-X SERVERS NEED FWUPDATE SUPPORT
<NOTE:2047847.1> - Fujitsu M10: Firmware for the Various Hardware Components used on Fujitsu M10