Asset ID: |
1-72-2056817.1 |
Update Date: | 2016-08-29 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2056817.1
:
A Minor Database Validation Error Was Detected On The MP Server During An Update. CFG-DB Validation Error
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
|
In this Document
Created from <SR 3-11337879481>
Applies to:
BNS Platform Hardware - Version DSR 5.0 and later
Information in this document applies to any platform.
Symptoms
A minor database validation error was detected on the MP server during an update. MP internal database is now out of sync with the configuration database. Subsequent database operations on the MP are ALLOWED. CFG-DB Validation Error
Changes
A new connection was added
Cause
The alarm that was appearing on the MP server is not a true alarm
When a new connection was added, there was an issue in binding to the TxPerConnqueue sysmetric and then alarm 19901 was raised.
The system corrected the TxPerConnqueue, but never cleared this alarm.
Solution
Executed the following command to clear the alarm:
alarm.put -e19901 -s 5