Symptoms
Changes
Cause
Solution


Created from <SR 3-11361315461>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

WWN not set on partition configuration.

Result of NBU Scan from new server:

Inquiry : "STK SL3000 4.31"
Vendor ID : "STK "
Product ID : "SL3000 "
Product Rev: "4.31"
Serial Number: "571000xxxxxx"
WWN : ""  <------------------------------------ not configured values
WWN Id Type : 0
Device Identifier: ""
Device Type : SDT_CHANGER
NetBackup Robot Type: 8
Removable : Yes
Device Supports: SCSI-5
Number of Drives : 0  <------------------------  not configured values
Number of Slots : 0    <------------------------  not configured values
Number of Media Access Ports: 0  <-----------  not configured values

Changes

 Customer using existing partition but moved to connections to another server.

Cause

 Incorrect WWPN entered.

Solution

Refer to SL3000 User's Guide -  look at " Partitioning with SLC ".    Note: SL3000 Library Docs are available on https://docs.oracle.com/cd/E28221_03/index.htm

Adding a FC-SCSI Host Connection
For FC-SCSI partitions, you must add a
host connection (HLI host-partition
connections are configured through the host library management software).
1. Select the Tools > Partitions > Summary (Step 2) tab.
2. In the Partition Allocation Summary area, select the partition.
3. Click Add Connection.
4. Enter the Initiator (WWPN) and LUN. Each initiator connected to the library must have one library partition assigned to LUN 0.
5. Click OK.
6. Repeat until you have added all required FC-SCSI connections. Each partition can have up to nine host connections, and each host can connect to multiple partitions.

Also Perform same step as above to delete connection.

 