![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 2055351.1 : Ipmitool Fails For Oemuser
Ipmitool Fails with: Error: Unable to establish LAN session Get SEL Info command failed Created from <SR 3-11045660191> Applies to:Exadata X3-2 Hardware - Version All Versions and laterInformation in this document applies to any platform. SymptomsOn a Linux-based Exadata X3-2 system, the ipmitool is failing for the oemuser on multiple nodes. It works fine on the nodes of another system. CauseThe ILOM snapshot for the system shows that ipmi is disabled. SolutionSet the servicestate to enabled. References<BUG:21755449> - EXADATA: IPMITOOL V. 1.8.12.1 IS FAILING FOR OEMUSER<BUG:20803418> - SOME MANUAL DESCRIPTION IS INCORRECT X5 DB SERVER ILOM <NOTE:1525155.1> - 12c or 11g Alerts on ILOM Target With Message Error: Unable to Establish IPMI v2 / RMCP+ session Attachments This solution has no attachment |
||||||||||||
|