Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2055351.1
Update Date:2015-09-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2055351.1 :   Ipmitool Fails For Oemuser  


Related Items
  • Exadata X3-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  


Ipmitool Fails with:
Error: Unable to establish LAN session
Get SEL Info command failed

Created from <SR 3-11045660191>

Applies to:

Exadata X3-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Symptoms

On a Linux-based Exadata X3-2 system, the ipmitool is failing for the oemuser on multiple nodes. It works fine on the nodes of another system.

When you try:

ipmitool -I lan -H -U oemuser -P <oemuser's password> -L USER sel list last 10

The system replies:
Error: Unable to establish LAN session
Get SEL Info command failed

Cause

The ILOM snapshot for the system shows that ipmi is disabled.
 
/SP/services/ipmi
  Properties:
  servicestate = disabled
 

Solution

Set the servicestate to enabled.

 

References

<BUG:21755449> - EXADATA: IPMITOOL V. 1.8.12.1 IS FAILING FOR OEMUSER
<BUG:20803418> - SOME MANUAL DESCRIPTION IS INCORRECT X5 DB SERVER ILOM