Symptoms
Cause
Solution
References


Created from <SR 3-11272865011>

Applies to:

Oracle Communications EAGLE (Software) - Version E5-MS 46.0 and later
Tekelec

Symptoms

Pre-upgrade backup fails on secondary server when in Failover mode.

Cause

The script seems to read host information from /Tekelec/WebNMS/classes/hbnlib/hibernate.cfg.xml and to access primary server for backup instead of secondary server

Solution

 Bug 21783617 has been opened for this issue. Will be resolved in GA release.

References

<BUG:21783617> - CDS: 46.2 UPGRADE - PRE-UPGRADE BACKUP FAILS ON SECONDARY SYSTEM