Solution Type
Problem Resolution Sure
Solution
2054281.1
:
Secondary Server Upgrade to 46.2.0 Fails At Pre-upgrade Backup
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
|
In this Document
Created from <SR 3-11272865011>
Applies to:
Oracle Communications EAGLE (Software) - Version E5-MS 46.0 and later
Tekelec
Symptoms
Pre-upgrade backup fails on secondary server when in Failover mode.
Cause
The script seems to read host information from /Tekelec/WebNMS/classes/hbnlib/hibernate.cfg.xml and to access primary server for backup instead of secondary server
Solution
Bug 21783617 has been opened for this issue. Will be resolved in GA release.
References
<BUG:21783617> - CDS: 46.2 UPGRADE - PRE-UPGRADE BACKUP FAILS ON SECONDARY SYSTEM