![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 2049795.1 : SuperCluster: Unable to Discover Griddisks on ASM After Patching Exadata Cell Servers to 12.1.2.1.0
Applies to:Oracle Exadata Storage Server Software - Version 12.1.2.1.0 to 12.1.2.2.0 [Release 12.1]Oracle SuperCluster T5-8 Half Rack - Version All Versions to All Versions [Release All Releases] Oracle SuperCluster T5-8 Full Rack - Version All Versions to All Versions [Release All Releases] SPARC SuperCluster T4-4 Half Rack - Version All Versions to All Versions [Release All Releases] Oracle SuperCluster M6-32 Hardware - Version All Versions to All Versions [Release All Releases] Oracle Solaris on SPARC (64-bit) SymptomsAfter upgrading the Exadata Image to 12.1.2.1.0 and above ,the ASM instance does not discover Gridisks from patched Exadata cell node kfod command returns no disks from upgraded Exadata cell node kfod disks=all op=disks ChangesUpgraded Cell to 12.1.2.1.0 and later Cause
Due to unpublished <Bug 20116094>, the ASM/kfod does not discover the Griddisks. Solution
The bug has been fixed in 11.2.0.3 BP 26 onwards Apply 11.2.0.3 BP 26 or one-off patch for Bug.20116094 to have a fix. (The patch must be applied on both Grid Home and RDBMS Home)
References<BUG:20116094> - ONECOMMAND: UNABLE TO GET MINIMUM NUMBER OF GRID DISKSAttachments This solution has no attachment |
||||||||||||
|