Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2048962.1
Update Date:2017-05-19
Keywords:

Solution Type  Problem Resolution Sure

Solution  2048962.1 :   T10000B - Drive I/O Errors  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-11246220682>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Drive I/O Errors

Type: T10000B    Rev: 1.50.203

2015-08-22 02:36:42
Drive 572004003640 had MIR_NOT_WRITABLE_AT_UNLOAD tapealert flag on the following tapes:  329635 (x1) 324280 (x1) 300975 (x1) 307831 (x1) 323805 (x1) 314916 (x1) 329346 (x1) 329712 (x1) 329865 (x1) 303349 (x1) 300493 (x1) 302126 (x3) 329634 (x1) tape(s)
Drive 572004003640 took multiple permanent servo head clog type errors.  This drive shows signs of problems with multiple tapes ( 12 ) and should be replaced.

2015-08-22 02:36:42
(SA-405) A servo head clog type error occurred on drive dddddddddddd tape vvvvvv FSC ffff. This has been determined to be a drive problem as it has occurred on other tapes in the past.

3337 - (10X)
Drive load failed due to media error,  hliLsm=8
302126T1 (x1) 323803T1 (x1) 326644T1 (x2) 329634T1 (x1) 329712T1 (x3) 329842T1 (x1) 329865T1 (x1)
(Errors Started - 2015-08-18 17:57:15 Errors Stopped - 2015-08-22 02:36:52)

3955 - (20X)
Error from device Code: 605 - Drive media error, drive 3,1,-2,1,2: load FAILED with mediaError:  (driveType = T10000b, driveFirmware = 1.50.203-5.30, sn = 572004003640) FSC: 5703
302126T1 (x3) 303349T1 (x1) 323803T1 (x1) 326644T1 (x2) 326658T1 (x1) 329380T1 (x1) 329618T1 (x3) 329634T1 (x1) 329669T1 (x1) 329712T1 (x3) 329842T1 (x1) 329865T1 (x1) 329867T1 (x1)
(Errors Started - 2015-08-14 15:13:58 Errors Stopped - 2015-08-22 02:36:52)

3992 - (35X)
Warning from device, drive 3,1,-2,1,2: rewindUnload Successful with mediaError: ,  FSC: 5703
Warning from device, drive 3,1,-2,1,2: rewindUnload Successful with mediaError: ,  FSC: 0000
300493T1 (x1) 300975T1 (x1) 302126T1 (x6) 303349T1 (x2) 307831T1 (x1) 314916T1 (x1) 323803T1 (x1) 323805T1 (x1) 324280T1 (x1) 326644T1 (x2) 326658T1 (x1) 329346T1 (x1) 329380T1 (x1) 329618T1 (x3) 329634T1 (x2) 329635T1 (x1) 329669T1 (x1) 329712T1 (x4) 329842T1 (x1) 329865T1 (x2) 329867T1 (x1)
(Errors Started - 2015-08-14 15:13:58 Errors Stopped - 2015-08-22 02:36:52)

Cause

 Servo head errors.

Solution

Replace the tape drive.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback