![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2046704.1 : SL3000/SL8500 - Screen Resolution on new OP Panels
In this Document
Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterSun StorageTek SL8500 Modular Library System - Version All Versions and later Information in this document applies to any platform. SymptomsThe screen resolution was changed on Local Operator Panels when the OS is loaded with Oracle Enterprise Linux. The original generation of Local Operator Panels were loaded with Windows and DSL Linux and are not impacted. The splash screen can be observed on boot up. CauseDesign Change. SolutionOn the latest generation of Local Operator Panels loaded with Oracle Enterprise Linux do not downgrade the code below 6.5x or a problem with the screen resolution will be observed, the SLC window will not fill up the screen.
What products are effected? Is there a serial number break-in? -No, only impacts panels loaded with OEL, been shipping for at least a year.
-During boot up this screen reflects the OS loading.
-Not with the addition of the new OS.
-At SLC 6.5x, the OS can also be identified in SLConsole; Tools—Diagnostics—OpPanel—OL2.6.x Attachments This solution has no attachment |
||||||||||||||||
|