Asset ID: |
1-72-2045976.1 |
Update Date: | 2017-07-11 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2045976.1
:
Infiniband Switch Ports disabled even though not configured in autodisable
Related Items |
- Sun Datacenter InfiniBand Switch 36
|
Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
|
IB Ports can become disabled even though they are NOT configured in autodisable
In this Document
Created from <SR 3-11155103831>
Applies to:
Sun Datacenter InfiniBand Switch 36 - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Infiniband switch port disabled even when NOT in the autodisable list
Cause
Customer reboots his HP media server and port 7A gets disabled. I had the customer remove port 7A from autodisable but it still gets disabled. Customer has discovered that configuring port 17A in autodisable causes port 7A to be affected. Configuring port 1xA or 1xB will also affect 0xA or 0xB. eg adding port 15B in autodisable will ALSO configure port 5B. See bug 21689700 - autodisable add 17A also affects port 7A
Solution
Use "autodisable none" to workaround this issue whilst engineering investigates Bug 21689700. Possibly, remove 17A (in this case) to stop 7A being affected.
Attachments
This solution has no attachment