Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2045761.1
Update Date:2017-09-21
Keywords:

Solution Type  Problem Resolution Sure

Solution  2045761.1 :   T10000A/B - Intermittent Drive Interface Failures  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
  • Sun StorageTek 9940A Tape Drive
  •  
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek 9940B Tape Drive
  •  
  • Sun StorageTek 9840 Tape Drive
  •  
  • StorageTek T10000D Tape Drive
  •  
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel

Applies to:

Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek 9840 Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek 9940B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

 Brocade switch code v7.4.0a brought in new functionality (ELS RDP frames) that causes problems in the drive interface only on T10000A and T10000B and older drives.  It also affect the T10000C and T10000D drives however there will be a future code change for this problem for these models. All 9x40 models are also affected.

Cause

Brocade switch code v7.4.0a brought in new functionality (ELS RDP frames) that causes problems in the drive interface only on T10000A and T10000B and older drives.  This brought out a hole on the Qlogic code running in the tape drives.  The tape drive should reject this frame but it does not. 

Solution

For all Storagetek Tape Drives Disable the RDP polling on the switch.

Note that the RDP polling cycle defaults to 1 hour (polls every hour unless rejected) in the switch FOS v7.4.0 code and above.

RDP is disabled by default in older switch code, so this 1 hour default is what has exposed the issue.

 

Process:

The RDP function can be turned off by setting the RDP polling interval to 0.

This can be done on the fly and should be set off for any switches with Oracle T10KA/B tape devices attached.

The RDP function can be turned off following these steps in the switch configuration.

 

Enter switch “configure” command, reply ‘y’ to Fabric parameters,  press enter until the RDP polling Cycle option is presented enter ‘0’ to disable it.

The press enter again until it exits and saves the configuration options.

  • configure

configure...

 

  Fabric parameters (yes, y, no, n): [no] y

    WWN Based persistent PID (yes, y, no, n): [no]

    Allow XISL Use (yes, y, no, n): [yes]

    Dynamic Portname (on, off): [off]

    Edge Hold Time(Low(80ms), Medium(220ms), High(500ms): (80..500) [220]

    Remote Fosexec feature: (on, off): [off]

    High Integrity Fabric Mode (yes, y, no, n): [yes]

  D-Port Parameters (yes, y, no, n): [no]

  RDP Polling Cycle(hours)[0 = Disable Polling]: (0..24) [1] 0