Solution Type  Problem Resolution Sure

Solution  2044845.1 :   HIPR2 cards in the control shelf may lock OAM cards off the IMT  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-11177374381>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 44.0.2 and later
Information in this document applies to any platform.

Symptoms

It can happen, that OAM cards are locked off the IMT by HIPR2 cards in the control shelf.

Cause

Eagle - R44: HIPR2 cards in the control shelf may lock OAM cards off the IMT

Solution

E5-MASP could not brought in service due to a known issue in Eagle Software Release 44.0

Bulletin TN003545 is attached

After rebooting the IMT A and IMT B bus, the E5-MASP cards were tested and both cards could be in-service. Issue cleared after the IMT reset and E5-MASP came back in-service again.