![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2044820.1 : SL150 - Degraded After The First Mount of Cleaning Cartridge, 9030,DRIVE_NEEDS_CLEANING
In this Document
Created from <SR 3-11198401081> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. The firmware version of the drives is "258S" and the firmware version of the SL150 is "2.50". The tape SL150 is attached exclusively to Oracle Zero Data Loss Recovery appliance. The connection are using two dedicated switch with 8GBps as throughput. The SL150's 2 Partition (DD and ZDLRA) SymptomsThe SL150 library (new) appears to be degraded after the first mount. O,0074,2015-08-10T11:45:52.337,9030,DRIVE_NEEDS_CLEANING,1,Module 2 Bottom DriveAssembly,,,,,,,,,Ensure cleaning tape is available. Initiate drive cleaning CauseThis is a firmware issue. Engineering verified that the problem here is the same as Bug 21563799 [https://bug.oraclecorp.com/pls/bug/webbug_edit.edit_info_top?rptno=21563799] [https://bug.oraclecorp.com/pls/bug/webbug_edit.edit_info_top?rptno=21563799] - BUI media property incorrectly shows EXP (expired) for a new cleaning media. SolutionThe fix is in 2.60 code. Library Patch: 23031875
Attachments This solution has no attachment |
||||||||||||||||
|