Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2044432.1
Update Date:2017-09-21
Keywords:

Solution Type  Problem Resolution Sure

Solution  2044432.1 :   T10000A/B/C/D - Guidelines For 3480 Errors  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
  • StorageTek T10000D Tape Drive
  •  
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel

Applies to:

Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek T10000A Tape Drive - Version All Versions and later
Sun StorageTek T10000B Tape Drive - Version All Versions and later
StorageTek T10000C Tape Drive - Version All Versions and later
StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

3480 Error(s)

FSC3480

Cause

FSC Dictionary Description:
MODEL = T10000A/B/C/D
FSC = 3480
(FSC Match Found in Rev. 4.08)


FSC: 3480 DC_FSC_RO_HLU_CRC_ERROR

MIM Code: TOLERANCE

FRU: HARDWARE CONF: 100%

Summary: |INVALID UCODE |REGISTER VALUE | *** |

Field Text:
This symptom indicates that there was a CRC Error on a data transfer.

Solution

 If you find that a T10000 tape drive takes more than 1 3480 the drive should be replaced.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback