![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2041807.1 : T10000D - SFP Problems And Information
In this Document
Applies to:StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsIf an improper T10000D SFP is installed neither port will work. CauseImproper SFP Installed. SolutionThe T10000D drive ships with a 16 GB SFP installed. This is the SFP that should be used in the drive. The drive can be hard set to run at 16, 8 or 4 GB with this SFP installed. An 8 GB SFP will also work in the drive, however, if a 4 GB SFP is installed in the drive then neither port will work. The drive will not do 2 GB at all as it has a 16 GB chipset in the drive which only handles 16, 8, and 4 GB transfer rates. Attachments This solution has no attachment |
||||||||||||||||
|