Solution Type Problem Resolution Sure Solution 2038295.1 : SL500/SL3000/SL8500 - Drive Communication Time-out - Info message: Drive Tray Serial Number Needs to be Updated
In this Document
Created from <SR 3-11112767247> Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]Sun StorageTek SL500 Modular Library System - Version All Versions to All Versions [Release All Releases] Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsDrive_Bay36(1.2.-2.1.4) 1320 - (6X) Drive communication time-out 1,2,-2,1,4 (Errors Started - 2015-07-15 22:55:37 Errors Stopped - 2015-07-28 11:12:42) 3993 - (3X) Device added, device=drive (Errors Started - 2015-07-27 16:01:01 Errors Stopped - 2015-07-28 11:14:13) 3994 - (2X) Device removed, device=drive (Errors Started - 2015-07-27 15:54:33 Errors Stopped - 2015-07-27 16:08:46) 4064 - (2X) Info message: Drive tray Serial Number needs to be updated, device=drive (Errors Started - 2015-07-27 16:02:22 Errors Stopped - 2015-07-27 16:10:56) CauseAfter the drive has been replaced, the drive tray SN was not updated, therefore sending errors. SolutionThe document assumes you have downloaded and installed SL Console on your computer or that you are using a remote SL Console session installed on a server. It also assumes that you have network access to the library and admin credentials were set up.
Go into StorageTek Library Console and follow the below path:
Tools > Configuration > Choose Tray Serial Number tab -> Select "unknown" -> Enter New Serial Number -> Choose Apply.
Attachments This solution has no attachment |
||||||||||||||||
|