![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2035517.1 : Sun Storage 7000 Unified Storage System: Unable to create a pool on a 7x10 system (No disks available for selection)
In this Document
Created from <SR 3-10948653081> Applies to:Sun Storage 7410 Unified Storage System - Version All Versions to All Versions [Release All Releases]Sun Storage 7310 Unified Storage System - Version All Versions to All Versions [Release All Releases] Sun Storage 7210 Unified Storage System - Version All Versions to All Versions [Release All Releases] Sun Storage 7110 Unified Storage System - Version All Versions to All Versions [Release All Releases] 7000 Appliance OS (Fishworks) SymptomsOn remaking a data pool on a basic 7410 system with half a JBOD of disks only, we have one faulty disk that prevents the BUI or CLI from making a pool. No disks will be available for selection when trying to do so. ChangesReconfiguring a pool with half a JBOD's worth of disks
CauseUnfortunately one missing or 'dead' disk - including a logzilla - in this configuration, will not allow a pool to be made as the BUI or CLI will regard this as an unsupported configuration.
SolutionReplace all 'broken' disks until the JBOD has a full 1/2 set of working data and logzilla drives.
Attachments This solution has no attachment |
||||||||||||||||||
|