Symptoms
Changes
Cause
Solution


Created from <SR 3-10948653081>

Applies to:

Sun Storage 7410 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7310 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7210 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7110 Unified Storage System - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Symptoms

On remaking a data pool on a basic 7410 system with half a JBOD of disks only, we have one faulty disk that prevents the BUI or CLI from making a pool.

No disks will be available for selection when trying to do so.

Changes

Reconfiguring a pool with half a JBOD's worth of disks

 

Cause

Unfortunately one missing or 'dead' disk - including a logzilla - in this configuration, will not allow a pool to be made as the BUI or CLI will regard this as an unsupported configuration.

 

 

Solution

Replace all 'broken' disks until the JBOD has a full 1/2 set of working data and logzilla drives.

 

 


Attachments
This solution has no attachment