![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2031593.1 : SL150 - Uncompression Error, Message " Kernel Panic.." On Screen. Library Is Not Operational
In this Document
Created from <SR 3-11025342721> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsSystem stopped responding. System rebooted. "Uncompression Error ...Kernel Panic..." is shown on the screen at reboot. Library is unable to boot and hangs. Reboot has no effect and problem remains with same failure message. Factory reset not possible. No diagnostics possible as library and GUI totally unresponsive. ChangesNone CauseRobot logic failure. SolutionAttempts to remove screen and replace had no effect. Expansion modules were removed and this too had no effect. KLM was replaced. No Effect. Attempts made to reboot with no USB stick in bot failed. Replaced the robot and issue was resolved. Attachments This solution has no attachment |
||||||||||||||||||
|