Solution Type  Problem Resolution Sure

Solution  2027592.1 :   SuperCluster: Garbage Characters show in Asmmodestatus, Asmdeactivationoutcome Fields  


Related Items
  • Oracle Exadata Storage Server Software
  •  
  • SPARC SuperCluster T4-4
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>SPARC SuperCluster>DB: SuperCluster_EST
  •  


When list griddisk attributes asmmodestatus command executed from cellcli can list a string of garbage characters when run on dismounted griddisks with a Solaris DB node.

Applies to:

SPARC SuperCluster T4-4 - Version All Versions and later
Oracle Exadata Storage Server Software - Version 11.2.2.4.0 to 12.1.1.1.2 [Release 11.2 to 12.1]
Information in this document applies to any platform.

Symptoms

When list griddisk attributes asmmodestatus command executed from cellcli can list a string of garbage characters when run on
dismounted griddisks with a Solaris SPARC DB node:

DATA7_SI_CD_00_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_01_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_02_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_03_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_04_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_05_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_06_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_07_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_08_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_09_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_10_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾
DATA7_SI_CD_11_myexadm03    ÃŠÃ¾ÂºÂ¾         Êþº¾

 

Changes


Cause

This is internal/unpublished Bug 19555017 - GARBAGE CHARACTERS IN ASMMODESTATUS, ASMDEACTIVATIONOUTCOME FIELDS:

REDISCOVERY INFORMATION:
 
If asmmodestatus ever shows up as garbage characters via cellcli, this bug may still exist.
 
WORKAROUND:
 
None



The error is specific to Sparc Supercluster environments and only occurs when the DB node has different endianness than the storage cell.

This error will not occur on a Exadata system running Solaris X86 as the endianness is the same.

 

Solution

This bug is fixed in the latest image of Storage cell Software (12.1.2.1.0 or later).