![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2027359.1 : Unable to complete Solaris 11.2 installation text menu, due to WARNINGS about firmware upgrade needed for Emulex FC HBA cards
In this Document
Created from <SR 3-10993432041> Applies to:SPARC T4-1 - Version All Versions to All Versions [Release All Releases]Solaris Operating System - Version 11.2 to 11.2 [Release 11.0] Information in this document applies to any platform. Symptoms
WARNING: emlxs0: Firmware update required.
(To trigger an update, a manual HBA or link reset using luxadm, fcadm, or emlxadm is required.) WARNING: emlxs1: Firmware update required. (To trigger an update, a manual HBA or link reset using luxadm, fcadm, or emlxadm is required.)
CauseEmulex FC HBA card firmware update messages disrupt Solaris installation text menu. Solution1. Reboot the server a few times , this should allow completion of the Solaris installation text menu. If that does fix the problem, try this workaround Workaround: Upgrade the firmware of the FC HBA by booting off Install Media and going into shell. From the shell run "fcinfo hba-port" command to get list of the fc hba port c# seen by media vs those seen by host OS instance. Then follow this document to upgrade firmware: Firmware Update Required. (A Manual Hba Reset Or Link Reset (Using Luxadm Or Fcadm) Is Required (Doc ID 1356876.1) As explained on that document you will need to run: luxadm -e forcelip /dev/cfg/c#
(# is controller number) on c# listed by "fcinfo hba-port" command while booted of Install Media.
See also: FAQ on Emulex HBA Boot Code/Fcode Firmware and driver patching (Doc ID 1351617.1) References<NOTE:1356876.1> - Firmware Update Required. (A Manual Hba Reset Or Link Reset (Using Luxadm Or Fcadm) Is Required<NOTE:1351617.1> - FAQ on Emulex HBA Boot Code/Fcode Firmware and driver patching Attachments This solution has no attachment |
||||||||||||||||||
|