Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2027359.1
Update Date:2017-05-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2027359.1 :   Unable to complete Solaris 11.2 installation text menu, due to WARNINGS about firmware upgrade needed for Emulex FC HBA cards  


Related Items
  • SPARC T4-1
  •  
  • Solaris Operating System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-10993432041>

Applies to:

SPARC T4-1 - Version All Versions to All Versions [Release All Releases]
Solaris Operating System - Version 11.2 to 11.2 [Release 11.0]
Information in this document applies to any platform.

Symptoms


- Boot command boots the preinstalled solaris image, and it gets to the solaris installation text menu, but then they get WARNINGS about firmware upgrade needed for emulex cards breaking into the console session, so customer cannot complete the Solaris setup.

WARNING: emlxs0: Firmware update required.
(To trigger an update, a manual HBA or link reset using luxadm, fcadm, or emlxadm is required.)
WARNING: emlxs1: Firmware update required.
(To trigger an update, a manual HBA or link reset using luxadm, fcadm, or emlxadm is required.)

 

Cause

Emulex FC HBA card firmware update messages disrupt Solaris installation text menu.
 

Solution

1. Reboot the server a few times , this should allow completion of the Solaris installation text menu.

If that does fix the problem, try this workaround

Workaround:

Upgrade the firmware of the FC HBA by booting off Install Media and going into shell.

From the shell run "fcinfo hba-port" command to get list of the fc hba port c# seen by media vs those seen by host OS instance.

Then follow this document to upgrade firmware:

Firmware Update Required. (A Manual Hba Reset Or Link Reset (Using Luxadm Or Fcadm) Is Required (Doc ID 1356876.1)

As explained on that document you will need to run:

luxadm -e forcelip /dev/cfg/c#

   (# is controller number)

on c# listed by "fcinfo hba-port" command while booted of Install Media.

 

See also:

FAQ on Emulex HBA Boot Code/Fcode Firmware and driver patching (Doc ID 1351617.1)

References

<NOTE:1356876.1> - Firmware Update Required. (A Manual Hba Reset Or Link Reset (Using Luxadm Or Fcadm) Is Required
<NOTE:1351617.1> - FAQ on Emulex HBA Boot Code/Fcode Firmware and driver patching