![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2023355.1 : VSM - SLS6684I & SLS6625E messages on T10000B Tape Drive on different tapes
In this Document
Created from <SR 3-10947449121> Applies to:Sun StorageTek T10000B Tape Drive - Version Not Applicable and laterInformation in this document applies to any platform. SymptomsCustomer see this error message: SLS6684I RTD V1A00384 ON VTSS VSMU11 RETURNED ECAM ERROR CC=5 RC=108 FSC 3691 CauseYou find the FSC T10000B error message here (byte 11 and 12): SLS6625E RTD V1A00384 REPORTED WRITE DATA CHK: 0A442025B53DD22037003961395E3961351703000A9D1080CE0E5021157600FF This error message 3961 say: FSC Dictionary Description: Summary: |WRITE - WS MEDIA| RATE ERROR | *** | SolutionIf the customer has this message on different tapes, replace this Tape Drive. Attachments This solution has no attachment |
||||||||||||||||
|