Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2021859.1
Update Date:2017-06-29
Keywords:

Solution Type  Problem Resolution Sure

Solution  2021859.1 :   Disk Error During MASP Upgrade on Standby MASP 1113  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-10925026711>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 40.x and later
Information in this document applies to any platform.

Symptoms

During MASP upgrade on standby MASP 1113 the following disk error message appears:

Card 1115 Module dmshc_utl.c Line 1062 DMS Error
Error Reading Active Partition Table 2 on standby TDM (A)

 

Cause

Either the card is faulty or there is a conflict at the time of the table reading
 

Solution

The user ran a copy-disk a second time it worked, which indicates a conflict at the time of the table reading. No further steps needed.
 