Solution Type  Problem Resolution Sure

Solution  2021757.1 :   Sun SPARC(R) Enterprise M4000/M5000 (OPL) Servers: Server fails to start /Poweron canceled due to missing component  


Related Items
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-10885843449>

Applies to:

Sun SPARC Enterprise M5000 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise M4000 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

After a power supply was replaced in an M4000, the system failed to come up.

XSCF> poweron -a
DomainIDs to power on:00
Continue? [y|n] :y
00 :Not powering on :Poweron canceled due to missing component.


XSCF> showboards -a
XSB  DID(LSB) Assignment  Pwr  Conn Conf Test    Fault
---- -------- ----------- ---- ---- ---- ------- --------
00-0 00(00)   Assigned    n    n    n    Unknown Faulted

 

Changes

Although the replacefru command was not used to replace the power supply, this was corrected and the system still wouldn't come up after a power cycle.

No failures were noted in the showstatus, however, many components were in a deconfigured state, and no components were missing in showhardconf.

We compared the problemmatic showhardconf to that of a known good lab system to verify.

 

Cause

 Note the "Dual" status for the Power_Supply_System variable.

SPARC Enterprise M4000;
   + Serial:BEFXXXXXX; Operator_Panel_Switch:Locked;
   + Power_Supply_System:Dual; SCF-ID:XSCF#0;


Dual power cannot be used on the M4000 using 100 Volts incoming power.

Per the setdualpowerfeed manpage:


Note -    The ability to enable and disable dual power feed is
            available  on  M3000/M4000/M5000  servers only. How-
            ever, dual power feed mode cannot be used with  100V
            power  on  M4000/M5000  servers.


This state should be "Single" for M4000/M5000 using 100 Volts incoming power.

SPARC Enterprise M4000;
    + Serial:BEFXXXXXXX; Operator_Panel_Switch:Locked;
    + Power_Supply_System:Single; SCF-ID:XSCF#0;

 

Solution

 Use the setdualpowerfeed command to disable the "Dual" option.

XSCF> setdualpowerfeed -s disable

    
Dual power feed will be disabled the next time the platform is powered on.

You will need to perfrom a power cycle after running the command and verify the problem is resolved.

Once the system is powered back on:

 

1. Run a showstatus from the XSCF, it  should show no errors:

XSCF> showstatus
No failures found in System Initialization.

2. Power on the domain(s):

XSCF> poweron -a
DomainIDs to power on:00
Continue? [y|n] :y

 