Solution Type Problem Resolution Sure Solution 2018127.1 : Luxadm -e Offline Generates Error: Can't Acquire "/devices/scsi_vhci/ssd@...:c,raw": Bad File Number
In this Document
Created from <SR 3-10857971361> Applies to:SPARC T4-1 - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. Symptomsluxadm -e offline fails with Bad file number message: CauseThe device is an EMC device. SolutionStopping the EMC UniSphere agent freed up the device and allowed the luxadm -e offline command to complete successfully. If you are not using EMC Unisphere software then this knowledge doc does not apply to your situation and more analysis is needed. Attachments This solution has no attachment |
||||||||||||||||
|