Solution Type  Problem Resolution Sure

Solution  2018127.1 :   Luxadm -e Offline Generates Error: Can't Acquire "/devices/scsi_vhci/ssd@...:c,raw": Bad File Number  


Related Items
  • SPARC T4-1
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-10857971361>

Applies to:

SPARC T4-1 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

luxadm -e offline fails with Bad file number message:


# luxadm -e offline /dev/rdsk/c0t6006016074E0280079CF804C3609E511d0s2
Error: can't acquire "/devices/scsi_vhci/ssd@g6006016074e0280079cf804c3609e511:c,raw": Bad file number

Cause

The device is an EMC device.
The customer is running EMC UniSphere software.

The customer stopped the EMC UniSphere agent and then he was able to offline the device.
 
The EMC UniSphere agent was keeping the device busy and that caused the luxadm -e offline to fail.

Once the agent was stopped then the luxadm -e offline command worked successfully.
 

Solution

Stopping the EMC UniSphere agent freed up the device and allowed the luxadm -e offline command to complete successfully.
 