Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2017681.1
Update Date:2017-07-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  2017681.1 :   SL8500-SL3000: VOLID Missing After Firmware Upgrade  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-10818379248>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

SL3000 / SL8500, No longer displaying VOLID on drive status page in SLConsole.

Changes

 Library firmware upgraded to SL3000 - 4.31 and SL8500 - 8.35.

Cause

Library code bug.

Solution

Engineering note:

Fix is scheduled for the next SL8500 release at 8.50 tentatively scheduled for 9/2015 and the following release for the SL3000. The SL3000 code release schedule is still pending but highly likely to be CYQ1_2016."

 

Workaround:

To display VOLID when drive is loaded. In SLConsole > Reports > Cartridge Table > sort Location Type column to group drive for easy viewing. Please refer to attachment.

 Report to display drive loaded with VOLID


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.