Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2017338.1
Update Date:2016-01-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  2017338.1 :   OAKERR:8006 Error in VNC Display Configurations  


Related Items
  • Oracle Database Appliance
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  




Applies to:

Oracle Database Appliance - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 

After deploying the VM, connected the the vm using following command:

oakcli show vmconsole <vmname>

But it disconnects session after 20-30 sec with message:

OAKERR:8006 Error in VNC display configuration : DISPLAY=:1.0

Cause

This is usually seen due to one of the following bugs:

Bug 20517723  LNX64-121-CMT:ADD VNCPORT BACK TO 'OAKCLI SHOW VM'

Bug 21245627  VNC SESSION OF VM CONSOLE CLOSES UNEXPECTEDLY OAKERR:8006 ERROR IN VNC DISPLAY

Solution

Per Bug 21245627  VNC SESSION OF VM CONSOLE CLOSES UNEXPECTEDLY OAKERR:8006 ERROR IN VNC DISPLAY

1) Upgrade ODA to 12.1.2.5

If this does not resolve the issue then:

 

Per Bug 20517723  LNX64-121-CMT:ADD VNCPORT BACK TO 'OAKCLI SHOW VM'

1) Using sendkeys feature you can configure the IP address for the DomU remotely from oda_base at firstboot. Then ssh to the vm via the IP. Details of send key are here : http://www.oracle.com/technetwork/database/database-appliance/overview/oda-automatedvmprovisioning-2348232.pdf

--or-

2) Login to the vm via same command 'oakcli show vmconsole', and configure the IP address for the vm by updating the ifcfg-ethX file before the vnc gets killed. And then do ssh to the vm.

Once the vm has been configured with a IP address, you can start a vncserver inside the vm and then use the vnc directly to the vm.

References

<BUG:20517723> - LNX64-121-CMT:ADD VNCPORT BACK TO 'OAKCLI SHOW VM'
<BUG:21245627> - VNC SESSION OF VM CONSOLE CLOSES UNEXPECTEDLY OAKERR:8006 ERROR IN VNC DISPLAY